Repeated monsoon leaks into a commercial top floor despite two previous coatings.

Commercial polyurea roof waterproofing in HITEC City
  • Multiple ceiling patches
  • Ponding at HVAC penetrations

Problem

Repeated monsoon leaks into a commercial top floor despite two previous coatings.

Inspection

Full roof walk, penetration schedule, thermal scan of the floor below.

Evidence

Failures clustered at HVAC kerbs and expansion joints, not the field of the old coat.

Diagnosis — Confirmed

Untreated penetrations and joints under a coating that had been applied over them.

Treatment

Joint and kerb detailing, then specified polyurea system.

Testing

Pond test on bays that hold water; leak watch on the floor below.

Warranty quoted

Quoted 7-year polyurea system. Later equipment installs through the roof must be re-detailed.