What you are seeing
How Gracia diagnoses
Tap test, thermal on the soffit below, moisture where the surface allows. The report names a minimum opening if we still need to verify. “Break all tiles” is not a diagnosis.
Large-format tiles in Madhapur and Gachibowli showers make guesswork demolition expensive. We would rather spend the first visit on the scan.
Multiple evidence points support the cause.
Evidence indicates the cause; further verification may still be required.
One or more clues exist, but the evidence is not enough for a firm conclusion.
Inspected, and no supporting evidence found in the inspected area.
What the Leak Diagnostic Report contains → · Thermal diagnosis cluster
Local case

Problem. Water marks on the living-room ceiling under a first-floor bathroom after every shower.
Evidence. Moisture concentrated at the bathroom floor-wall junction, not at the tap line.
Probable. Failed wet-area membrane at the floor-wall joint. Concealed pipe leak not supported by the scan; excluded pending any opening.
Treatment. Injection grouting at the joint, two-coat wet-area system. Plumbing left in place — not in scope.
Testing. Shower test after curing; ceiling below checked the next day.
Full case study →Questions
Thermal on the ceiling below, tap test, grout and threshold inspection, moisture meter on adjacent plaster. That narrows the zone. Opening is the last step, at the point the evidence names.